You're currently on:

THERMOCOUPLES

+ BEADED WIRE THERMOCOUPLE

+ WASHER STYLE THERMOCOUPLE

+ TUBE AND WIRE PROBE

+ BAYONET THERMOCOUPLE

+ STANDARD AND MINI PLUG THERMOCOUPLE

+ TRANSITION THERMOCOUPLE

+ INDUSTRIAL HEAD THERMOCOUPLE

+ CEMENT AND STICK ON THERMOCOUPLES

COMMON THERMOCOUPLE TEMPERATURE RANGES
CALIBRATION TEMPERATURE RANGE STD. LIMITS OF ERROR SPEC. LIMITS OF ERROR
J 0 °C to 750 °C
(32°F to 1382 °F)
Greater of 2.2 °C
Or 0.75%
Greater of 1.1 °C
or 0.4%
K -200 °C to 1250 °C
(328 °F to 2282 °F)
Greater of 2.2 °C
Or 0.75%
Greater of 1.1 °C
or 0.4%
E -200 °C to 900 °C
(-328 °F to 1652 °F)
Greater of 1.7 °C
Or 0.5%
Greater of 1.0 °C
or 0.4%
T -250 °C to 350 °C
(-328 °F to 662 °F)
Greater of 1.0 °C
Or 0.75%
Greater of 0.5 °C
or 0.4%


MINERAL INSULATED THERMOCOUPLES

• Useable under severe conditions
• Withstands temperatures up to metal melting point
• Withstands corrosive conditions limited only by the choice of sheath material
• Can be formed to a minimum radius of twice the sheath diameter without loss of integrity
• Available in a wide variety of diameters from .010” to .500”
• Available in standard and special limits of error
• Can withstand external pressures up to 50,000 psi
• Dual element cable is available
COMMON THERMOCOUPLE TEMPERATURE RANGES
Sheath Material Code Max. Temp. In Air Melting Point
304SS A 1650 °F (900 °C) 2550 °F (1400 °C)
310SS D 2000 °F (1090 °C) 2550 °F (1400 °C)
316SS F 1650 °F (900 °C) 2500 °F (1370 °C)
Inconel® 600* Q 2000 °F (1090 °C) 2470 °F (1350 °C)
Hastelloy® C-276 H 1900 °F (1037 °C) 2415 °F (1320 °C)
Hastelloy® B2 I 2500 °F (1370 °C)
Hastelloy® X L 2470 °F (1355 °C)
Titanium** T 600 °F (315 °C) 3135 °F (1725 °C)
Tantaium O 900 °F (480 °C) 5425 °F (2995 °C)
Molybdenum*** P 500 °F (260 °C) 4730 °F (2610 °C)
Pit. 10% Rhodium X 2825 °F (1550 °C) 3362 °F (1850 °C)
Pit. 20% Rhodium Y 3000 °F (1650 °C) 3452 °F (1900 °C)
Monel® M 2372 °F (1300 °C) 2462 °F (1350 °C

*Not recommended for use in Sulfur atmospheres.
**Titanium is not recommeded for use in air above 600 ºF due to oxidation.
*** Refractory metals are extremely sensitive to Oxygen and must be used in vacuum or inert gas such as Helium or Argon.

**Calibration Symbol
Chromel-Alumel K
Iron-Constantan J
Copper-Constantan T
Chromel-Constantan E
90% Platinum - 10% Rhodium vs. Platinum S
70% Plantinum - 30% Rhodium vs. 94% Plantinum 6% Rhodium B
Tungsten 5% Rhenium vs. Tungsten 26% Rhenium C

** Other calibrations available. Consult sales.

MULTIPOINT THERMOCOUPLES


STANDARD OUTSIDE DIAMETER & MAXIMUM LENGTHS
O.D. Tolerance Max. # of Points Normal Length Max Length Notes
.313” +/- .003” (7.95mm) Up to 19 250 feet 500 feet Type K Max 2100 ºF
.250” +/- .002” (6.35mm) Up to 13 400 feet 800 feet Type K Max 2100 ºF
.188” +/- .002” (4.78mm) Up to 10 700 feet 1400 feet Type K Max 2100 ºF
.125” +/- .002” (7.95mm) Up to 7 1600 feet 3200 feet Type K Max 1960 ºF

WALL THICKNESS & WIRE DIAMETERS
Number of Thermocouple Measuring Points Wall Thickness (% of Diameter) Outer Wire Diameter (% of Diameter) Inner Wire Diameter (% of Diameter)
2-4 11.8% 11.0% 15.5%
5-7 11.8% 8.5% 11.7%
8-10 11.8% 8.0% 10.3%
11-13 11.8% 7.6% 11.4%
14-16 11.8% 7.2% 12.1%
17-19 7.8% 7.3% 14.3%

Click here to view our Thermocouples guide.